PR-310

Extended

Differential Pressure Transmitter

Capacitive DP cell for flow, filter and level-by-pressure duties.

ACCURACY

±0.075 % of span

RANGE

0

to

16

bar

PROTECTION

IP66

TEMPERATURE

-40

to

120

°C

PR-310 Differential Pressure Transmitter | INSTRAVA0.82

01

OVERVIEW

What it does and why it is built this way

The PR-310 measures the difference between two pressures, which makes it the standard choice for flow across an orifice, filter condition and hydrostatic level.

A capacitive cell with a fully welded isolating diaphragm gives high accuracy on spans as small as 10 mbar and survives static pressures up to 160 bar.

KEY FEATURES

±0.075 % of span with 10-year stability

Remote-seal ready for hot or viscous media

Dual-compartment housing, Ex d (demo)

MEASURING PRINCIPLE

Capacitive differential pressure

How this principle works →

OUTPUT SIGNALS

4–20 mA

HART

Foundation Fieldbus

APPROVALS (DEMO)

Hazardous-area protection (Ex d)

Functional safety SIL 2 capable

Pressure-equipment conformity

02

HOW IT MEASURES

Measuring principle, animated

Drag the slider to see how the measured variable becomes a 4–20 mA signal.

Capacitive differential pressure
PR-310 Differential Pressure Transmitter | INSTRAVASTRAIN GAUGES · ΔR ∝ DEFLECTIONPROCESS PRESSURE
PRESSURE
8.00 bar
OUTPUT
12.0 mA
  1. Process pressure deflects a thin diaphragm.
  2. Strain gauges on the diaphragm change resistance.
  3. A bridge circuit converts the change into a 4–20 mA signal.

03

SPECIFICATIONS

Technical data

Technical specifications
GroupParameterValue
MeasurementPrincipleCapacitive differential pressure
Measuring range0 to 16 bar
Accuracy±0.075 % of span
Static pressure limit160 bar
Long-term stability±0.1 % of URL over 10 years
OutputSignals4–20 mA, HART, Foundation Fieldbus
ProcessConnectionFlange
Process temperature-40 to 120 °C
Wetted materials316L, Hastelloy C, tantalum
EnvironmentIngress protectionIP66
Ambient temperature−40 to 85 °C
ApprovalsApprovals (demo)Hazardous-area protection (Ex d), Functional safety SIL 2 capable, Pressure-equipment conformity
ElectricalSupply voltage10.5–42 V DC

Values are illustrative demo data for a fictional product. Replace with your own specifications.

07

FAQ

Questions about this principle

No questions listed yet.

RFQ

REQUEST A QUOTE

Specify it for your application

Tell us the fluid, range and installation. We will confirm the right model and send a quotation within two working days.