TM-310
Temperature
Head-Mount Temperature Transmitter
Universal RTD / thermocouple conditioning with digital output.
ACCURACY
±0.1 °C (RTD)
PROTECTION
IP66
TM-210
Fundamental
Type K, J and N assemblies for high-temperature process lines.
ACCURACY
Class 1 (±1.5 °C or 0.4 %)
RANGE
-40
to
1100
°C
PROTECTION
IP65
TEMPERATURE
-40
to
1100
°C
01
OVERVIEW
The TM-210 uses a thermocouple junction for fast response and a very wide range, to 1,100 °C. It suits furnaces, flue gas and exhaust applications.
Mineral-insulated sheaths resist vibration and can be bent on site to fit awkward installations.
KEY FEATURES
Type K, J and N elements
Mineral-insulated, vibration resistant
Rugged ceramic terminal block
MEASURING PRINCIPLE
How this principle works →
OUTPUT SIGNALS
4–20 mA
APPROVALS (DEMO)
Hazardous-area protection (Ex d)
02
HOW IT MEASURES
Drag the slider to see how the measured variable becomes a 4–20 mA signal.
03
SPECIFICATIONS
| Group | Parameter | Value |
|---|---|---|
| Measurement | Principle | Thermocouple |
| Measuring range | -40 to 1,100 °C | |
| Accuracy | Class 1 (±1.5 °C or 0.4 %) | |
| Types | K, J, N | |
| Tolerance | Class 1 (±1.5 °C or 0.4 %) | |
| Output | Signals | 4–20 mA |
| Process | Connection | Threaded |
| Process temperature | -40 to 1100 °C | |
| Sheath | Inconel 600, 3 to 8 mm | |
| Response time T90 | < 3 s | |
| Environment | Ingress protection | IP65 |
| Approvals | Approvals (demo) | Hazardous-area protection (Ex d) |
Values are illustrative demo data for a fictional product. Replace with your own specifications.
04
DOCUMENTS
Downloads are direct. No forms, no accounts.
05
APPLICATIONS
Nothing to show yet.
07
FAQ
No questions listed yet.
RFQ
REQUEST A QUOTE
Tell us the fluid, range and installation. We will confirm the right model and send a quotation within two working days.